NBS-ODSYS-MIB :: nbsOdsysCcThermThreshHiErr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNBS-ODSYS-MIBnbsOdsysCcThermThreshHiErr

nbsOdsysCcThermThreshHiErr

Module: NBS-ODSYS-MIB

OID (symbolic): NBS-ODSYS-MIB::nbsOdsysCcThermThreshHiErr

OID (numeric): 1.3.6.1.4.1.629.228.3.1.1.44

Node type: OBJECT-TYPE

Type: NbsTcTemperature

Access: read-only

Description: Indicates the maximum functional operating temperature, in degrees celsius

What is nbsOdsysCcThermThreshHiErr?

This OID gives the maximum functional operating temperature, in degrees Celsius, for a control card before it's considered to have failed on the high end. An admin uses it as the upper error boundary when evaluating nbsOdsysCcThermActual readings.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.228.3.1.1.44
snmpwalk -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysCcThermThreshHiErr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.228.3.1.1.44.1
snmpget -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysCcThermThreshHiErr.1

Start monitoring MRV Opti-Driver optical chassis (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-ODSYS-MIB::nbsOdsysCcThermThreshHiErr OID value, configure state conditions and alerts, and monitor any MRV Opti-Driver optical chassis (hardware inventory) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.228nbsOdsysMibNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.3nbsOdsysCcGrpNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.3.1nbsOdsysCcTableNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.3.1.1nbsOdsysCcEntryNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.3.1.1.44nbsOdsysCcThermThreshHiErrNBS-ODSYS-MIB