All MIBs › NBS-CMMC-MIB › nbsCmmcSysObIpAddr
nbsCmmcSysObIpAddr
Module: NBS-CMMC-MIB
OID (symbolic): NBS-CMMC-MIB::nbsCmmcSysObIpAddr
OID (numeric): 1.3.6.1.4.1.629.200.3.1.7
Node type: OBJECT-TYPE
Type: IpAddress
Access: read-write
Description: The SNMP Agent Administrative value of the IP Address for the out-band access.
This value is stored in the system NVRAM. The current operational IP Adress may be obtained by accessing the ipAdEntAddr entry in the ipAddrTable, for ipAdEntIfIndex equal to the SLIP interface value.
If the system has no current operational Out-Band IP Address, meaning that, the access is done in-band, then this value takes effect immediately. In this case the NetMask and the BcastAddr will be automa- tically built. Otherwise it will take effect after a system reset
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.3.1.7 snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcSysObIpAddr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.3.1.7.1 snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcSysObIpAddr.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.629.200.3.1.7.1 a <value>
Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcSysObIpAddr OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.629 | nbase | GSWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.629.200 | nbsCmmcMib | NBS-CMMC-MIB |
| 1.3.6.1.4.1.629.200.3 | nbsCmmcIpSnmpGrp | NBS-CMMC-MIB |
| 1.3.6.1.4.1.629.200.3.1 | nbsCmmcIpCfg | NBS-CMMC-MIB |
| 1.3.6.1.4.1.629.200.3.1.7 | nbsCmmcSysObIpAddr | NBS-CMMC-MIB |