NBS-CMMC-MIB :: nbsCmmcSysNVAreaStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNBS-CMMC-MIBnbsCmmcSysNVAreaStatus

nbsCmmcSysNVAreaStatus

Module: NBS-CMMC-MIB

OID (symbolic): NBS-CMMC-MIB::nbsCmmcSysNVAreaStatus

OID (numeric): 1.3.6.1.4.1.629.200.2.3001.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: invalid(1) indicates this entry is not a valid NV area.

primary(2) indicates this entry is the primary NV area. The next time the hardware is reset, this image will be loaded. This setting may be changed via nbsCmmcChassisNVAreaAdmin or nbsCmmcSlotNVAreaAdmin.

backup(3) indicates this entry is the backup NV area. The next time the hardware is reset, this image will be loaded if the primary image fails to load. This image is subject to being overwritten if a new image is downloaded and there are no other banks available.

erased(4) indicates this entry refers to an area that was erased and is no longer in the NV storage area.

busy(5) indicates this NV area is busy.

What is nbsCmmcSysNVAreaStatus?

This object indicates the operational status of a non-volatile memory (NV) area on the NBS device, such as whether it contains a valid, primary, or backup firmware image. The primary NV area's image will be loaded when the hardware resets, while the backup image loads if the primary fails. An operator monitors this to track which firmware versions are stored and ready for deployment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.2.3001.1.3
snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcSysNVAreaStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.2.3001.1.3.1
snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcSysNVAreaStatus.1

Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcSysNVAreaStatus OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.200nbsCmmcMibNBS-CMMC-MIB
1.3.6.1.4.1.629.200.2nbsCmmcSystemGrpNBS-CMMC-MIB
1.3.6.1.4.1.629.200.2.3001nbsCmmcSysNVAreaTableNBS-CMMC-MIB
1.3.6.1.4.1.629.200.2.3001.1nbsCmmcSysNVAreaEntryNBS-CMMC-MIB
1.3.6.1.4.1.629.200.2.3001.1.3nbsCmmcSysNVAreaStatusNBS-CMMC-MIB