NBS-CMMC-MIB :: nbsCmmcPortTemperatureLevel

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNBS-CMMC-MIBnbsCmmcPortTemperatureLevel

nbsCmmcPortTemperatureLevel

Module: NBS-CMMC-MIB

OID (symbolic): NBS-CMMC-MIB::nbsCmmcPortTemperatureLevel

OID (numeric): 1.3.6.1.4.1.629.200.8.1.1.64

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object indicates whether this port has a temperature problem.

If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1).

If Digital Diagnostics indicate temperature is below the low Alarm Threshold, this value should be lowAlarm(2).

If Digital Diagnostics indicate temperature is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3).

If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4).

If Digital Diagnostics indicate temperature is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),.

If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6).

The related object nbsCmmcPortTemperature indicates what the current temperature is.

What is nbsCmmcPortTemperatureLevel?

This OID shows the temperature status of a network port (normal, warning, or alarm). It indicates whether a port is overheating based on built-in temperature sensors. A technician checks this value during troubleshooting if a port stops working, as overheating often causes hardware failure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.64
snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortTemperatureLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.64.1
snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortTemperatureLevel.1

Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcPortTemperatureLevel OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.200nbsCmmcMibNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8nbsCmmcPortGrpNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1nbsCmmcPortTableNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1.1nbsCmmcPortEntryNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1.1.64nbsCmmcPortTemperatureLevelNBS-CMMC-MIB