All MIBs › NBS-CMMC-MIB › nbsCmmcPortSupplyVoltsLevel
nbsCmmcPortSupplyVoltsLevel
Module: NBS-CMMC-MIB
OID (symbolic): NBS-CMMC-MIB::nbsCmmcPortSupplyVoltsLevel
OID (numeric): 1.3.6.1.4.1.629.200.8.1.1.68
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object indicates whether this port has a problem with the electric voltage across the port.
If this port does not support SFF-8472 Digital Diagnostics, this value should be notSupported(1).
If Digital Diagnostics indicate SupplyVolts is below the low Alarm Threshold, this value should be lowAlarm(2).
If Digital Diagnostics indicate SupplyVolts is above the low Alarm Threshold but below the low Warning threshold, this value should be lowWarning(3).
If Digital Diagnostics indicate this port is within the recommended operating range, value is ok(4).
If Digital Diagnostics indicate SupplyVolts is higher than the high Warning threshold, but has not crossed the Alarm threshold, this value should be highWarning (5),.
If Digital Diagnostics indicate this port has crossed the high Alarm threshold, this value should be highAlarm(6).
The related object nbsCmmcPortSupplyVolts indicates what the current supply voltage is.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.68 snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortSupplyVoltsLevel
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.68.1 snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortSupplyVoltsLevel.1
Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcPortSupplyVoltsLevel OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.629 | nbase | GSWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.629.200 | nbsCmmcMib | NBS-CMMC-MIB |
| 1.3.6.1.4.1.629.200.8 | nbsCmmcPortGrp | NBS-CMMC-MIB |
| 1.3.6.1.4.1.629.200.8.1 | nbsCmmcPortTable | NBS-CMMC-MIB |
| 1.3.6.1.4.1.629.200.8.1.1 | nbsCmmcPortEntry | NBS-CMMC-MIB |