nbsCmmcPortRedundantTxMode

Module: NBS-CMMC-MIB

OID (symbolic): NBS-CMMC-MIB::nbsCmmcPortRedundantTxMode

OID (numeric): 1.3.6.1.4.1.629.200.8.1.1.78

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object determines whether or not a redundant port's transmitter should be shut down when that port is on standby.

If both redundant ports are connected (via a Y cable) to the same remote port, use the setting oneColonOne (2). This 1:1 configuration will turn off the standby transmitter so it will not interfere with the active port.

If each redundant port is connected to its own remote port, use the setting onePlusOne(3). 1+1 leaves both transmitters on, so the remote site can read its link status.

Any changes to this object are automatically applied to this port's redundant pair.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.78
snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortRedundantTxMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.78.1
snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortRedundantTxMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.629.200.8.1.1.78.1 i <value>

Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcPortRedundantTxMode OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.200nbsCmmcMibNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8nbsCmmcPortGrpNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1nbsCmmcPortTableNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1.1nbsCmmcPortEntryNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1.1.78nbsCmmcPortRedundantTxModeNBS-CMMC-MIB