NBS-CMMC-MIB :: nbsCmmcPortMDIPinoutAdmin

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NBS-CMMC-MIB › nbsCmmcPortMDIPinoutAdmin

nbsCmmcPortMDIPinoutAdmin

Module: NBS-CMMC-MIB

OID (symbolic): NBS-CMMC-MIB::nbsCmmcPortMDIPinoutAdmin

OID (numeric): 1.3.6.1.4.1.629.200.8.1.1.57

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Connecting twisted-pair ethernet ports originally required care in choosing either straight or crossover cables. Later, many ethernet ports added the feature that they could be configured to accept either cable pinout. Some ports are even smart enough to detect, or autosense, the pinout they should use.

This Administrative object allows users to request the port adopt a specific pinout, or to have the port autosense it.

The value notSupported(1) indicates that this port cannot dynamically alter its pinout through this object.

The value mdi(2) is used to connect with a straight cable to mdix ports such as those found on hubs, switches and routers.

The value mdix(3) is used to connect with a straight cable to mdi ports such as those found on workstations.

The value autoSense(4) indicates this port should automatically detect and change to the necessary pinout.

This object has a corresponding Operational value which reports the actual pinout state. In certain situations, the Operational value might differ from the Administrative.

What is nbsCmmcPortMDIPinoutAdmin?

Administratively requests this twisted-pair Ethernet port's cable pinout: mdi(2) for connecting with a straight cable to mdix-style ports such as hubs, switches, and routers, mdix(3) for connecting with a straight cable to mdi-style ports such as workstations, or autoSense(4), the default, to let the port detect and adapt automatically. Admins override autoSense manually on a port that's misdetecting pinout with a particular cable or device combination.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.57
snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortMDIPinoutAdmin

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.8.1.1.57.1
snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcPortMDIPinoutAdmin.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.629.200.8.1.1.57.1 i <value>

Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcPortMDIPinoutAdmin OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseCORE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.200nbsCmmcMibNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8nbsCmmcPortGrpNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1nbsCmmcPortTableNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1.1nbsCmmcPortEntryNBS-CMMC-MIB
1.3.6.1.4.1.629.200.8.1.1.57nbsCmmcPortMDIPinoutAdminNBS-CMMC-MIB