NBS-CMMC-MIB :: nbsCmmcChassisFirmwareLoad

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNBS-CMMC-MIBnbsCmmcChassisFirmwareLoad

nbsCmmcChassisFirmwareLoad

Module: NBS-CMMC-MIB

OID (symbolic): NBS-CMMC-MIB::nbsCmmcChassisFirmwareLoad

OID (numeric): 1.3.6.1.4.1.629.200.6.1.1.44

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: This bitmask indicates which executable images this chassis has stored in its own NV area. This object is mandatory for all chassis.

OCTET STRING bitmasks count the leftmost bit (MSB) as 0. Bit 0 indicates whether an executable image is loading.

Subsequent bits refer to the nbsCmmcSysFirmwareTable. Bit 1 corresponds to the first table entry, Bit 2 to the second entry, and so on. A bit is set (1) if that image is stored on this chassis, cleared (0) if not.

Clearing bits has no effect. To erase an NV area, use the nbsCmmcSysNVAreaTable.

Users may transfer a file to an NV area by setting the appropriate file's bit and the loading (MSB) bit to one (1). Adding a file requires that the NM start a file transfer to this chassis, which is a lengthy operation. If a transfer session is already active (nbsCmmcChassisLoader is non-zero), writes to this object will be rejected.

A zero length OCTET STRING indicates that the nbsCmmcSysFirmwareTable is not supported by this agent.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.200.6.1.1.44
snmpwalk -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcChassisFirmwareLoad

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.200.6.1.1.44.1
snmpget -v2c -c public <target> NBS-CMMC-MIB::nbsCmmcChassisFirmwareLoad.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.629.200.6.1.1.44.1 s <value>

Start monitoring NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-CMMC-MIB::nbsCmmcChassisFirmwareLoad OID value, configure state conditions and alerts, and monitor any NBS chassis-based network shelf/multiplexer equipment (CMMC-controlled) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.200nbsCmmcMibNBS-CMMC-MIB
1.3.6.1.4.1.629.200.6nbsCmmcChassisGrpNBS-CMMC-MIB
1.3.6.1.4.1.629.200.6.1nbsCmmcChassisTableNBS-CMMC-MIB
1.3.6.1.4.1.629.200.6.1.1nbsCmmcChassisEntryNBS-CMMC-MIB
1.3.6.1.4.1.629.200.6.1.1.44nbsCmmcChassisFirmwareLoadNBS-CMMC-MIB