rebootWithResponse

Module: Motorola-Cpe-PRIVATE-MIB

OID (symbolic): Motorola-Cpe-PRIVATE-MIB::rebootWithResponse

OID (numeric): 1.3.6.1.4.1.10529.300.2.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: If reading this OID, rebootRequired(1) indicates a reboot is currently required, else, returns rebootNotRequired(0).

What is rebootWithResponse?

Read-write reboot control for the CPE: 1 means a reboot is pending, 0 means none is needed, and writing 255 asks the device to reboot. Its source DESCRIPTION is copied from the read-only reboot-required flag and only describes reading, so the 255 write behavior is inferred from the enum; for example, set 255 after pushing a config change that needs a restart.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10529.300.2.1
snmpwalk -v2c -c public <target> Motorola-Cpe-PRIVATE-MIB::rebootWithResponse

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10529.300.2.1.1
snmpget -v2c -c public <target> Motorola-Cpe-PRIVATE-MIB::rebootWithResponse.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10529.300.2.1.1 i <value>

Start monitoring Cambium Networks (Motorola/Gemtek heritage) PMP 320 WiMAX CPE unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Motorola-Cpe-PRIVATE-MIB::rebootWithResponse OID value, configure state conditions and alerts, and monitor any Cambium Networks (Motorola/Gemtek heritage) PMP 320 WiMAX CPE unit from a single console.

How to Use in IPNetwork Monitor

Select a Cambium Networks (Motorola/Gemtek heritage) PMP 320 WiMAX CPE unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rebootWithResponse into the Find box to locate it in the OID tree, then select it and click OK. It reports if reading this OID, rebootRequired(1) indicates a reboot is currently required, else, returns rebootNotRequired(0). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'rebootNotRequired', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10529gemtekMotorola-Cpe-PRIVATE-MIB
1.3.6.1.4.1.10529.300gemtekDevCpeMotorola-Cpe-PRIVATE-MIB
1.3.6.1.4.1.10529.300.2gemtekDevCpeControlMotorola-Cpe-PRIVATE-MIB
1.3.6.1.4.1.10529.300.2.1rebootWithResponseMotorola-Cpe-PRIVATE-MIB