myDevicePowerStatus

Module: MY-ENTITY-MIB

OID (symbolic): MY-ENTITY-MIB::myDevicePowerStatus

OID (numeric): 1.3.6.1.4.1.171.10.97.2.21.1.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The power status of device

What is myDevicePowerStatus?

Reports this device's redundant power supply (RPS) link state: no RPS link, linked but not powering, linked and ready, or actively linked and providing power. An admin checks this to confirm an external RPS unit is actually backing up this device rather than just being cabled in.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.10.97.2.21.1.2.1.4
snmpwalk -v2c -c public <target> MY-ENTITY-MIB::myDevicePowerStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.10.97.2.21.1.2.1.4.1
snmpget -v2c -c public <target> MY-ENTITY-MIB::myDevicePowerStatus.1

Start monitoring D-Link managed/stackable switch (hardware entity inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MY-ENTITY-MIB::myDevicePowerStatus OID value, configure state conditions and alerts, and monitor any D-Link managed/stackable switch (hardware entity inventory) from a single console.

How to Use in IPNetwork Monitor

Select a D-Link managed/stackable switch (hardware entity inventory) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type myDevicePowerStatus into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The power status of device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'rpsLinkAndPower', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.10dlink_productsDES-1226G-MIB
1.3.6.1.4.1.171.10.97switchMibMY-SMI
1.3.6.1.4.1.171.10.97.2myMgmtMY-SMI
Numeric OIDNameModule
1.3.6.1.4.1.171.10.97.2.21myEntityMIBMY-ENTITY-MIB
1.3.6.1.4.1.171.10.97.2.21.1myDeviceMIBObjectsMY-ENTITY-MIB
1.3.6.1.4.1.171.10.97.2.21.1.2myDeviceInfoTableMY-ENTITY-MIB
1.3.6.1.4.1.171.10.97.2.21.1.2.1myDeviceInfoEntryMY-ENTITY-MIB
1.3.6.1.4.1.171.10.97.2.21.1.2.1.4myDevicePowerStatusMY-ENTITY-MIB