MWRM-UNIT-MIB :: genEquipUnitIduPowerSupply2AlarmAdmin

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsMWRM-UNIT-MIBgenEquipUnitIduPowerSupply2AlarmAdmin

genEquipUnitIduPowerSupply2AlarmAdmin

Module: MWRM-UNIT-MIB

OID (symbolic): MWRM-UNIT-MIB::genEquipUnitIduPowerSupply2AlarmAdmin

OID (numeric): 1.3.6.1.4.1.2281.10.1.1.13

Node type: OBJECT-TYPE

Type: EnableDisable

Access: read-write

Description: This parameter is relevant only for IDU with more than two power supply units. The user can choose to disable (ignore the alarm) of one of the power supply units.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2281.10.1.1.13
snmpwalk -v2c -c public <target> MWRM-UNIT-MIB::genEquipUnitIduPowerSupply2AlarmAdmin

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2281.10.1.1.13.1
snmpget -v2c -c public <target> MWRM-UNIT-MIB::genEquipUnitIduPowerSupply2AlarmAdmin.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2281.10.1.1.13.1 s <value>

Start monitoring Microwave radio link terminal (indoor unit, vendor unconfirmed) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MWRM-UNIT-MIB::genEquipUnitIduPowerSupply2AlarmAdmin OID value, configure state conditions and alerts, and monitor any Microwave radio link terminal (indoor unit, vendor unconfirmed) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2281ceragonCERAGON-MIB
1.3.6.1.4.1.2281.10genEquipMWRM-PM-MIB
1.3.6.1.4.1.2281.10.1genEquipUnitMWRM-PM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2281.10.1.1genEquipUnitInfoMWRM-UNIT-MIB
1.3.6.1.4.1.2281.10.1.1.13genEquipUnitIduPowerSupply2AlarmAdminMWRM-UNIT-MIB