MOXA-NP6000-MIB :: socketTcpAliveCheck

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-NP6000-MIB › socketTcpAliveCheck

socketTcpAliveCheck

Module: MOXA-NP6000-MIB

OID (symbolic): MOXA-NP6000-MIB::socketTcpAliveCheck

OID (numeric): 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The TCP alive check time. 0 min: TCP connection will not be closed when the TCP connection is idle. 1 to 99 min: The NPort 6000 series device server automatically closes the TCP connection if there is no TCP activity for the given time. After the connection is closed, the NPort 6000 series device server starts listening for another Real COM driver Connection.

What is socketTcpAliveCheck?

In Socket (TCP Server/Client) mode, sets in minutes how long a TCP connection may sit idle before the NPort closes it and starts listening for a new one; 0 disables the timeout. An admin lowers this to recover a socket faster after a remote peer disappears without a clean disconnect.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.1
snmpwalk -v2c -c public <target> MOXA-NP6000-MIB::socketTcpAliveCheck

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.1.1
snmpget -v2c -c public <target> MOXA-NP6000-MIB::socketTcpAliveCheck.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.1.1 i <value>

Start monitoring Moxa NPort 6000 series secure serial device server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-NP6000-MIB::socketTcpAliveCheck OID value, configure state conditions and alerts, and monitor any Moxa NPort 6000 series secure serial device server from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
1.3.6.1.4.1.8691.2nportMOXA-CN2600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691.2.8np6000MOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1swMgmtMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4portSettingMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4.1opModeSettingMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4.1.2applicationMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4.1.2.2socketMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1socketTableMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1socketEntryMOXA-NP6000-MIB
1.3.6.1.4.1.8691.2.8.1.4.1.2.2.1.1.1socketTcpAliveCheckMOXA-NP6000-MIB