MOXA-EDS408A-MIB :: varturboRingCouplingPortChangedTrap

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-EDS408A-MIB › varturboRingCouplingPortChangedTrap

varturboRingCouplingPortChangedTrap

Module: MOXA-EDS408A-MIB

OID (symbolic): MOXA-EDS408A-MIB::varturboRingCouplingPortChangedTrap

OID (numeric): 1.3.6.1.4.1.8691.7.7.2.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The coupling path of Turbo Ring has been changed.

What is varturboRingCouplingPortChangedTrap?

Variable binding carried in the Turbo Ring coupling-port-changed notification: none(1) or couplingPortChanged(2). Admins read it in the trap payload to confirm the active coupling path just switched over.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.2.6
snmpwalk -v2c -c public <target> MOXA-EDS408A-MIB::varturboRingCouplingPortChangedTrap

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.2.6.1
snmpget -v2c -c public <target> MOXA-EDS408A-MIB::varturboRingCouplingPortChangedTrap.1

Start monitoring Moxa EDS-408A industrial Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-EDS408A-MIB::varturboRingCouplingPortChangedTrap OID value, configure state conditions and alerts, and monitor any Moxa EDS-408A industrial Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691.7industrialEthernetMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7eds408aMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.2swTrapsMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.2.6varturboRingCouplingPortChangedTrapMOXA-EDS408A-MIB