MOXA-EDS408A-MIB :: turboRingRdntPort1

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-EDS408A-MIB › turboRingRdntPort1

turboRingRdntPort1

Module: MOXA-EDS408A-MIB

OID (symbolic): MOXA-EDS408A-MIB::turboRingRdntPort1

OID (numeric): 1.3.6.1.4.1.8691.7.7.1.16.2.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The port number of 1st Redundant Port on the TURBO RING.

What is turboRingRdntPort1?

Port number configured as the 1st redundant port of the Turbo Ring. Admins set this to one of the two ring-uplink ports that connect this switch into the ring.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.1.16.2.7
snmpwalk -v2c -c public <target> MOXA-EDS408A-MIB::turboRingRdntPort1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.1.16.2.7.1
snmpget -v2c -c public <target> MOXA-EDS408A-MIB::turboRingRdntPort1.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8691.7.7.1.16.2.7.1 i <value>

Start monitoring Moxa EDS-408A industrial Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-EDS408A-MIB::turboRingRdntPort1 OID value, configure state conditions and alerts, and monitor any Moxa EDS-408A industrial Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691.7industrialEthernetMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7eds408aMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1swMgmtMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16commRedundancyMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16.2turboRingMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16.2.7turboRingRdntPort1MOXA-EDS408A-MIB