MOXA-EDS408A-MIB :: monitorLinkStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-EDS408A-MIB › monitorLinkStatus

monitorLinkStatus

Module: MOXA-EDS408A-MIB

OID (symbolic): MOXA-EDS408A-MIB::monitorLinkStatus

OID (numeric): 1.3.6.1.4.1.8691.7.7.1.10.3.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The port link status.

What is monitorLinkStatus?

Live link status of this port: disable(-1) if the port is administratively disabled, off(0) if no link, on(1) if link is up. Admins poll this per-port table as the primary real-time connectivity indicator.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.1.10.3.1.2
snmpwalk -v2c -c public <target> MOXA-EDS408A-MIB::monitorLinkStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.1.10.3.1.2.1
snmpget -v2c -c public <target> MOXA-EDS408A-MIB::monitorLinkStatus.1

Start monitoring Moxa EDS-408A industrial Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-EDS408A-MIB::monitorLinkStatus OID value, configure state conditions and alerts, and monitor any Moxa EDS-408A industrial Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691.7industrialEthernetMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7eds408aMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1swMgmtMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.10monitorMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.10.3monitorPortTableMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.10.3.1monitorPortEntryMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.10.3.1.2monitorLinkStatusMOXA-EDS408A-MIB