MOXA-EDS408A-MIB :: brokenStatusRing2

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MOXA-EDS408A-MIB › brokenStatusRing2

brokenStatusRing2

Module: MOXA-EDS408A-MIB

OID (symbolic): MOXA-EDS408A-MIB::brokenStatusRing2

OID (numeric): 1.3.6.1.4.1.8691.7.7.1.16.5.2.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: turboRingV2 broken display.

What is brokenStatusRing2?

Reports whether Turbo Ring v2 Ring 2 is currently broken: na(0), normal(1), broken(2). Admins treat broken(2) as an immediate signal to investigate a cable or switch failure somewhere in this ring.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.1.16.5.2.10
snmpwalk -v2c -c public <target> MOXA-EDS408A-MIB::brokenStatusRing2

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8691.7.7.1.16.5.2.10.1
snmpget -v2c -c public <target> MOXA-EDS408A-MIB::brokenStatusRing2.1

Start monitoring Moxa EDS-408A industrial Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MOXA-EDS408A-MIB::brokenStatusRing2 OID value, configure state conditions and alerts, and monitor any Moxa EDS-408A industrial Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8691moxaMOXA-CN2600-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8691.7industrialEthernetMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7eds408aMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1swMgmtMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16commRedundancyMOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16.5turboRingV2MOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16.5.2turboRingV2Ring2MOXA-EDS408A-MIB
1.3.6.1.4.1.8691.7.7.1.16.5.2.10brokenStatusRing2MOXA-EDS408A-MIB