MERIDIAN2-MIB :: gpsHP5071AIonPumpI

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › MERIDIAN2-MIB › gpsHP5071AIonPumpI

gpsHP5071AIonPumpI

Module: MERIDIAN2-MIB

OID (symbolic): MERIDIAN2-MIB::gpsHP5071AIonPumpI

OID (numeric): 1.3.6.1.4.1.13827.14.2.82

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: ASCII string showing the Cesium Ion Pump current in uA, typical range is 0 to 40 uA. It may be NOT INSTALLED if the HP5071A Cesium oscillator option is not installed.

What is gpsHP5071AIonPumpI?

An ASCII string reporting the optional HP5071A cesium oscillator's ion pump current, in microamps, typically 0 to 40 uA; reads NOT INSTALLED when the HP5071A option isn't present. A rising ion pump current over the tube's lifetime is a normal wear indicator tracked to anticipate eventual tube replacement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13827.14.2.82
snmpwalk -v2c -c public <target> MERIDIAN2-MIB::gpsHP5071AIonPumpI

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.13827.14.2.82.1
snmpget -v2c -c public <target> MERIDIAN2-MIB::gpsHP5071AIonPumpI.1

Start monitoring EndRun Technologies Meridian II GPS-disciplined time/frequency reference with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MERIDIAN2-MIB::gpsHP5071AIonPumpI OID value, configure state conditions and alerts, and monitor any EndRun Technologies Meridian II GPS-disciplined time/frequency reference from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.13827endRunTechnologiesMIBENDRUNTECHNOLOGIES-MIB
Numeric OIDNameModule
1.3.6.1.4.1.13827.14meridian2GPSMERIDIAN2-MIB
1.3.6.1.4.1.13827.14.2gpsMERIDIAN2-MIB
1.3.6.1.4.1.13827.14.2.82gpsHP5071AIonPumpIMERIDIAN2-MIB