LENOVO-ENV-MIB :: lenovoEnvMibFanSpeedPercent

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › LENOVO-ENV-MIB › lenovoEnvMibFanSpeedPercent

lenovoEnvMibFanSpeedPercent

Module: LENOVO-ENV-MIB

OID (symbolic): LENOVO-ENV-MIB::lenovoEnvMibFanSpeedPercent

OID (numeric): 1.3.6.1.4.1.19046.2.3.11.1.2.1.9

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Speed of the fan as a percentage

What is lenovoEnvMibFanSpeedPercent?

The fan's current speed expressed as a percentage of its maximum, giving an admin a quick way to see whether the cooling system is running at a normal, elevated, or maxed-out level in response to temperature.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19046.2.3.11.1.2.1.9
snmpwalk -v2c -c public <target> LENOVO-ENV-MIB::lenovoEnvMibFanSpeedPercent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19046.2.3.11.1.2.1.9.1
snmpget -v2c -c public <target> LENOVO-ENV-MIB::lenovoEnvMibFanSpeedPercent.1

Start monitoring Lenovo ThinkServer/System x rack or tower server (environmental sensors) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LENOVO-ENV-MIB::lenovoEnvMibFanSpeedPercent OID value, configure state conditions and alerts, and monitor any Lenovo ThinkServer/System x rack or tower server (environmental sensors) from a single console.

How to Use in IPNetwork Monitor

Select a Lenovo ThinkServer/System x rack or tower server (environmental sensors) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type lenovoEnvMibFanSpeedPercent into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the speed of the fan as a percentage. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the speed drops below the level expected for a healthy, spinning fan, since a stalled or slowing fan often precedes overheating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.19046lenovoLENOVO-SMI-MIB
1.3.6.1.4.1.19046.2lenovoNetworkMibsLENOVO-SMI-MIB
1.3.6.1.4.1.19046.2.3network_mibsLENOVO-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19046.2.3.11lenovoEnvMIBLENOVO-ENV-MIB
1.3.6.1.4.1.19046.2.3.11.1lenovoEnvMibObjectsLENOVO-ENV-MIB
1.3.6.1.4.1.19046.2.3.11.1.2lenovoEnvMibFanTableLENOVO-ENV-MIB
1.3.6.1.4.1.19046.2.3.11.1.2.1lenovoEnvMibFanEntryLENOVO-ENV-MIB
1.3.6.1.4.1.19046.2.3.11.1.2.1.9lenovoEnvMibFanSpeedPercentLENOVO-ENV-MIB