KENTIX-ROOT-MIB :: ambientInfoHumidityValue

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › KENTIX-ROOT-MIB › ambientInfoHumidityValue

ambientInfoHumidityValue

Module: KENTIX-ROOT-MIB

OID (symbolic): KENTIX-ROOT-MIB::ambientInfoHumidityValue

OID (numeric): 1.3.6.1.4.1.37954.10.1.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Current Humidity (In percent) Reading

What is ambientInfoHumidityValue?

This value reports the current relative humidity reading from this ambient sensor, as a percentage from 0 to 100. Admins track it alongside temperature since humidity outside a safe range threatens equipment reliability, whether too dry (static discharge risk) or too damp (condensation and corrosion risk). For example, a reading of 65 means 65% relative humidity, which an admin might flag if their environment's safe range tops out at 60%.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.37954.10.1.1.4
snmpwalk -v2c -c public <target> KENTIX-ROOT-MIB::ambientInfoHumidityValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.37954.10.1.1.4.1
snmpget -v2c -c public <target> KENTIX-ROOT-MIB::ambientInfoHumidityValue.1

Start monitoring Kentix environmental/security sensor appliance (root registration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the KENTIX-ROOT-MIB::ambientInfoHumidityValue OID value, configure state conditions and alerts, and monitor any Kentix environmental/security sensor appliance (root registration) from a single console.

How to Use in IPNetwork Monitor

Select a Kentix environmental/security sensor appliance (root registration) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ambientInfoHumidityValue into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the current Humidity (In percent) Reading. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.37954kentixKENTIX-ROOT-MIB
1.3.6.1.4.1.37954.10universalKENTIX-ROOT-MIB
1.3.6.1.4.1.37954.10.1hardwareKENTIX-ROOT-MIB
1.3.6.1.4.1.37954.10.1.1ambientInfoEntryKENTIX-ROOT-MIB
1.3.6.1.4.1.37954.10.1.1.4ambientInfoHumidityValueKENTIX-ROOT-MIB