All MIBs › Juniper-SSC-CLIENT-MIB › juniSscClientServerSwitchoverTimeout
juniSscClientServerSwitchoverTimeout
Module: Juniper-SSC-CLIENT-MIB
OID (symbolic): Juniper-SSC-CLIENT-MIB::juniSscClientServerSwitchoverTimeout
OID (numeric): 1.3.6.1.4.1.4874.2.2.36.1.1.1.1
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The server switchover timeout in seconds. The SSC Client begins with the primary server and proceeds rotationally to secondary, tertiary, primary, etc. as timeouts occur.
What is juniSscClientServerSwitchoverTimeout?
The number of seconds (5-300) the SSC Client waits for a response before rotating to the next configured server (primary, secondary, tertiary, and back); shortening it makes failover faster at the risk of flapping between servers under transient latency.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.36.1.1.1.1 snmpwalk -v2c -c public <target> Juniper-SSC-CLIENT-MIB::juniSscClientServerSwitchoverTimeout
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.36.1.1.1.1.1 snmpget -v2c -c public <target> Juniper-SSC-CLIENT-MIB::juniSscClientServerSwitchoverTimeout.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4874.2.2.36.1.1.1.1.1 i <value>
Start monitoring Juniper Networks E-series router running JUNOSe (Service Selection Center client) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Juniper-SSC-CLIENT-MIB::juniSscClientServerSwitchoverTimeout OID value, configure state conditions and alerts, and monitor any Juniper Networks E-series router running JUNOSe (Service Selection Center client) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4874 | juniperUni | Juniper-UNI-SMI |
| 1.3.6.1.4.1.4874.2 | juniperUniMibs | Juniper-UNI-SMI |
| 1.3.6.1.4.1.4874.2.2 | juniMibs | Juniper-MIBs |
| 1.3.6.1.4.1.4874.2.2.36 | juniSscClientMIB | Juniper-MIBs |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4874.2.2.36.1 | juniSscClientObjects | Juniper-SSC-CLIENT-MIB |
| 1.3.6.1.4.1.4874.2.2.36.1.1 | juniSscClientCfg | Juniper-SSC-CLIENT-MIB |
| 1.3.6.1.4.1.4874.2.2.36.1.1.1 | juniSscClientCfgScalars | Juniper-SSC-CLIENT-MIB |
| 1.3.6.1.4.1.4874.2.2.36.1.1.1.1 | juniSscClientServerSwitchoverTimeout | Juniper-SSC-CLIENT-MIB |