All MIBs › INXNMM-MIB › riLdcSlotTempCondition
riLdcSlotTempCondition
Module: INXNMM-MIB
OID (symbolic): INXNMM-MIB::riLdcSlotTempCondition
OID (numeric): 1.3.6.1.4.1.28.10.10.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The temperature status of the slot. When the slot is empty or when the module in the slot is in some other failure or error state, this variable returns unknown(60).
What is riLdcSlotTempCondition?
Reports the thermal status of the module in this slot, returning too-hot(62) to warn of an overheating condition worth investigating before a thermal shutdown occurs, and unknown(60) whenever the slot is empty or the module is in some other failure state.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.28.10.10.1.13 snmpwalk -v2c -c public <target> INXNMM-MIB::riLdcSlotTempCondition
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.28.10.10.1.13.1 snmpget -v2c -c public <target> INXNMM-MIB::riLdcSlotTempCondition.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> riLdcSlotTempCondition.1
Start monitoring Interlan (Micom-Interlan) NMM Ethernet management card with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INXNMM-MIB::riLdcSlotTempCondition OID value, configure state conditions and alerts, and monitor any Interlan (Micom-Interlan) NMM Ethernet management card from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.28 | interlan | INXNMM-MIB |
| 1.3.6.1.4.1.28.10 | riLdcNmm | INXNMM-MIB |
| 1.3.6.1.4.1.28.10.10 | riLdcChassisSlotTable | INXNMM-MIB |
| 1.3.6.1.4.1.28.10.10.1 | riLdcSlotEntry | INXNMM-MIB |
| 1.3.6.1.4.1.28.10.10.1.13 | riLdcSlotTempCondition | INXNMM-MIB |