All MIBs › INTEL-SERVER-BASEBOARD7 › discreteCoolingDevicePerformance
discreteCoolingDevicePerformance
Module: INTEL-SERVER-BASEBOARD7
OID (symbolic): INTEL-SERVER-BASEBOARD7::discreteCoolingDevicePerformance
OID (numeric): 1.3.6.1.4.1.343.2.10.3.5.600.30.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Describes whether or not the discrete cooling device meets performance standards, or is lagging.
What is discreteCoolingDevicePerformance?
Indicates whether this discrete cooling device is meeting its expected performance standard (met) or falling short (lags). It's a secondary quality flag that can catch a fan trending toward marginal performance before discreteCoolingDeviceStatus reports an outright fault.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.343.2.10.3.5.600.30.1.6 snmpwalk -v2c -c public <target> INTEL-SERVER-BASEBOARD7::discreteCoolingDevicePerformance
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.343.2.10.3.5.600.30.1.6.1 snmpget -v2c -c public <target> INTEL-SERVER-BASEBOARD7::discreteCoolingDevicePerformance.1
Start monitoring Intel server baseboard (Server Management Software subagent) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INTEL-SERVER-BASEBOARD7::discreteCoolingDevicePerformance OID value, configure state conditions and alerts, and monitor any Intel server baseboard (Server Management Software subagent) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.343 | intel | AOLAN-MIB |
| 1.3.6.1.4.1.343.2 | products | AOLAN-MIB |
| 1.3.6.1.4.1.343.2.10 | server_management | Intel-Common-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.343.2.10.3 | software | INTEL-SERVER-BASEBOARD7 |
| 1.3.6.1.4.1.343.2.10.3.5 | baseboardGroup7 | INTEL-SERVER-BASEBOARD7 |
| 1.3.6.1.4.1.343.2.10.3.5.600 | thermalGroup | INTEL-SERVER-BASEBOARD7 |
| 1.3.6.1.4.1.343.2.10.3.5.600.30 | discreteCoolingDeviceTable | INTEL-SERVER-BASEBOARD7 |
| 1.3.6.1.4.1.343.2.10.3.5.600.30.1 | discreteCoolingDeviceTableEntry | INTEL-SERVER-BASEBOARD7 |
| 1.3.6.1.4.1.343.2.10.3.5.600.30.1.6 | discreteCoolingDevicePerformance | INTEL-SERVER-BASEBOARD7 |