INTEL-SERVER-BASEBOARD7 :: coolingDeviceUpperNonRecoverableThreshold

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › INTEL-SERVER-BASEBOARD7 › coolingDeviceUpperNonRecoverableThreshold

coolingDeviceUpperNonRecoverableThreshold

Module: INTEL-SERVER-BASEBOARD7

OID (symbolic): INTEL-SERVER-BASEBOARD7::coolingDeviceUpperNonRecoverableThreshold

OID (numeric): 1.3.6.1.4.1.343.2.10.3.5.600.20.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute contains the fatal error threshold level for the fan. The threshold is given in the units specified by the Fan Units attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'.

What is coolingDeviceUpperNonRecoverableThreshold?

Sets the upper non-recoverable speed threshold for this fan -- an unusually high reading treated as a fatal fault (this attribute may not apply to all fan types). It's the top alerting tier, though for most fans the more operationally relevant thresholds are on the lower (too-slow) side.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.343.2.10.3.5.600.20.1.7
snmpwalk -v2c -c public <target> INTEL-SERVER-BASEBOARD7::coolingDeviceUpperNonRecoverableThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.343.2.10.3.5.600.20.1.7.1
snmpget -v2c -c public <target> INTEL-SERVER-BASEBOARD7::coolingDeviceUpperNonRecoverableThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.343.2.10.3.5.600.20.1.7.1 i <value>

Start monitoring Intel server baseboard (Server Management Software subagent) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INTEL-SERVER-BASEBOARD7::coolingDeviceUpperNonRecoverableThreshold OID value, configure state conditions and alerts, and monitor any Intel server baseboard (Server Management Software subagent) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.343intelAOLAN-MIB
1.3.6.1.4.1.343.2productsAOLAN-MIB
1.3.6.1.4.1.343.2.10server_managementIntel-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.343.2.10.3softwareINTEL-SERVER-BASEBOARD7
1.3.6.1.4.1.343.2.10.3.5baseboardGroup7INTEL-SERVER-BASEBOARD7
1.3.6.1.4.1.343.2.10.3.5.600thermalGroupINTEL-SERVER-BASEBOARD7
1.3.6.1.4.1.343.2.10.3.5.600.20coolingDeviceTableINTEL-SERVER-BASEBOARD7
1.3.6.1.4.1.343.2.10.3.5.600.20.1coolingDeviceTableEntryINTEL-SERVER-BASEBOARD7
1.3.6.1.4.1.343.2.10.3.5.600.20.1.7coolingDeviceUpperNonRecoverableThresholdINTEL-SERVER-BASEBOARD7