All MIBs › INNOVX-CASCADE-LIU-MIB › cascadeDiagTestDuration
cascadeDiagTestDuration
Module: INNOVX-CASCADE-LIU-MIB
OID (symbolic): INNOVX-CASCADE-LIU-MIB::cascadeDiagTestDuration
OID (numeric): 1.3.6.1.4.1.498.22.1.4.4.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Defines the length of all LIU diagnostic tests.
What is cascadeDiagTestDuration?
Sets how long the currently selected LIU diagnostic test runs (1, 5, 10, or 20 minutes).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.22.1.4.4.2 snmpwalk -v2c -c public <target> INNOVX-CASCADE-LIU-MIB::cascadeDiagTestDuration
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.22.1.4.4.2.1 snmpget -v2c -c public <target> INNOVX-CASCADE-LIU-MIB::cascadeDiagTestDuration.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.22.1.4.4.2.1 i <value>
Start monitoring InnoVX/GDC Cascade line interface unit (LIU) card, T1/E1 with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INNOVX-CASCADE-LIU-MIB::cascadeDiagTestDuration OID value, configure state conditions and alerts, and monitor any InnoVX/GDC Cascade line interface unit (LIU) card, T1/E1 from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | DMA200-MIB |
| 1.3.6.1.4.1.498.22 | framerelay | INNOVX-CORE-MIB |
| 1.3.6.1.4.1.498.22.1 | innovx | INNOVX-CORE-MIB |
| 1.3.6.1.4.1.498.22.1.4 | casGroup | INNOVX-CORE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.22.1.4.4 | diagnostics | INNOVX-CASCADE-LIU-MIB |
| 1.3.6.1.4.1.498.22.1.4.4.2 | cascadeDiagTestDuration | INNOVX-CASCADE-LIU-MIB |