INFORMANT-MSCS :: mscsResourceSeparateMonitor

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › INFORMANT-MSCS › mscsResourceSeparateMonitor

mscsResourceSeparateMonitor

Module: INFORMANT-MSCS

OID (symbolic): INFORMANT-MSCS::mscsResourceSeparateMonitor

OID (numeric): 1.3.6.1.4.1.9600.1.31.11.1.20

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: The SeparateMonitor property indicates whether the resource requires its own Resource Monitor.

The data value for the SeparateMonitor property can be set to TRUE or FALSE. To use a debugger with a resource DLL, the resource's SeparateMonitor property must be set to TRUE.

A change to the SeparateMonitor property does not take effect immediately unless the resource is offline at the time of the change. If the resource is online, the change takes effect after the resource is taken offline and brought back online.

What is mscsResourceSeparateMonitor?

This read-only boolean indicates whether a specific resource runs in its own dedicated Resource Monitor process rather than sharing one with other resources; it must be TRUE to attach a debugger to that resource, and a change only takes effect once the resource is taken offline and back online. An admin developing or debugging a custom resource DLL checks this to confirm the resource is isolated in its own monitor before attaching a debugger.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9600.1.31.11.1.20
snmpwalk -v2c -c public <target> INFORMANT-MSCS::mscsResourceSeparateMonitor

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9600.1.31.11.1.20.1
snmpget -v2c -c public <target> INFORMANT-MSCS::mscsResourceSeparateMonitor.1

Start monitoring Windows Server failover cluster node (Microsoft Cluster Server, SNMP Informant) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INFORMANT-MSCS::mscsResourceSeparateMonitor OID value, configure state conditions and alerts, and monitor any Windows Server failover cluster node (Microsoft Cluster Server, SNMP Informant) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9600wtcsWTCS
1.3.6.1.4.1.9600.1informantWTCS
Numeric OIDNameModule
1.3.6.1.4.1.9600.1.31mscsINFORMANT-MSCS
1.3.6.1.4.1.9600.1.31.11mscsResourceTableINFORMANT-MSCS
1.3.6.1.4.1.9600.1.31.11.1mscsResourceEntryINFORMANT-MSCS
1.3.6.1.4.1.9600.1.31.11.1.20mscsResourceSeparateMonitorINFORMANT-MSCS