INFORMANT-MSCS :: mscsNodeHighestVersion

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › INFORMANT-MSCS › mscsNodeHighestVersion

mscsNodeHighestVersion

Module: INFORMANT-MSCS

OID (symbolic): INFORMANT-MSCS::mscsNodeHighestVersion

OID (numeric): 1.3.6.1.4.1.9600.1.31.7.1.12

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The NodeHighestVersion property specifies the highest possible version of the Cluster service with which the node can join or communicate. The following table summarizes the attributes of the NodeHighestVersion property.

The value of NodeHighestVersion is set when the Cluster service is installed or upgraded on a node. The upper 16 bits of the value store the version number, while the lower 16 bits describe the build number. For more information on how the Cluster service creates and uses version numbers, see Version Compatibility.

What is mscsNodeHighestVersion?

This read-only value reports the highest Cluster service version a specific node can join or communicate with, packed into a 32-bit value where the upper 16 bits are the version number and the lower 16 bits are the build number, set when the Cluster service is installed or upgraded on that node. An admin checks this alongside mscsNodeLowestVersion when planning to add a node running a different Cluster service release.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9600.1.31.7.1.12
snmpwalk -v2c -c public <target> INFORMANT-MSCS::mscsNodeHighestVersion

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9600.1.31.7.1.12.1
snmpget -v2c -c public <target> INFORMANT-MSCS::mscsNodeHighestVersion.1

Start monitoring Windows Server failover cluster node (Microsoft Cluster Server, SNMP Informant) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INFORMANT-MSCS::mscsNodeHighestVersion OID value, configure state conditions and alerts, and monitor any Windows Server failover cluster node (Microsoft Cluster Server, SNMP Informant) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9600wtcsWTCS
1.3.6.1.4.1.9600.1informantWTCS
Numeric OIDNameModule
1.3.6.1.4.1.9600.1.31mscsINFORMANT-MSCS
1.3.6.1.4.1.9600.1.31.7mscsNodeTableINFORMANT-MSCS
1.3.6.1.4.1.9600.1.31.7.1mscsNodeEntryINFORMANT-MSCS
1.3.6.1.4.1.9600.1.31.7.1.12mscsNodeHighestVersionINFORMANT-MSCS