IFT-SNMP-MIB :: ctlrCfgModeFlags

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › IFT-SNMP-MIB › ctlrCfgModeFlags

ctlrCfgModeFlags

Module: IFT-SNMP-MIB

OID (symbolic): IFT-SNMP-MIB::ctlrCfgModeFlags

OID (numeric): 1.3.6.1.4.1.1714.1.1.1.12

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Controller configuration mode flags BIT 0 : Write Back Status (RW) 0: Disabled, 1: Enabled. BIT 1 : Motor Spin Up (RW) 0: Disabled, 1: Enabled. BIT 2 : Power Up SCSI Reset (RW) 0: Disabled, 1: Enabled. BIT 8 : Battery Backup Supported (RO) 0: Not Supported, 1: Supported. BIT 9 : Battery Backup Present (RO) 0: Absent, 1: Present. BIT 12 : ECC Function 0: Disabled, 1: Enabled BIT 15 : JBOD Mode (RW) - This should be ignored if 'JBOD Mode Supported' is not set. 0: Disabled, 1: Enabled. BIT 16 : LUN Assignment by SCSI ID (RO) 0: Not Supported, 1: Supported. BIT 17 : Support SCSI LUN > 0 (RO) BIT 18 : Spanning Logical Drive Support 0: Not Supported, 1: Supported. BIT 19 : JBOD Mode Supported (RO) 0: Not Supported, 1: Supported. BIT 20 -- BIT 32 : Reserved.

What is ctlrCfgModeFlags?

A read-write bitmask of controller-wide configuration switches: bit 0 toggles write-back caching, bit 1 toggles motor spin-up, bit 2 toggles power-up SCSI reset, and higher bits report (read-only) whether battery backup and JBOD mode are supported/present. An admin sets this to turn features like write-back caching on or off, e.g. clearing bit 0 forces the controller into the safer but slower write-through mode.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1714.1.1.1.12
snmpwalk -v2c -c public <target> IFT-SNMP-MIB::ctlrCfgModeFlags

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1714.1.1.1.12.1
snmpget -v2c -c public <target> IFT-SNMP-MIB::ctlrCfgModeFlags.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1714.1.1.1.12.1 i <value>

Start monitoring Infortrend EonStor/ESDS RAID storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IFT-SNMP-MIB::ctlrCfgModeFlags OID value, configure state conditions and alerts, and monitor any Infortrend EonStor/ESDS RAID storage controller from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1714infortrendIFT-SNMP-MIB
1.3.6.1.4.1.1714.1extInterfaceIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.1ctlrConfigurationIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.1.1sysInformationIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.1.1.12ctlrCfgModeFlagsIFT-SNMP-MIB