Module: IFT-SNMP-MIB

OID (symbolic): IFT-SNMP-MIB::chlMode

OID (numeric): 1.3.6.1.4.1.1714.1.7.1.8

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Channel mode flags BIT 0 : Channel Mode (RW) 0: Drive Mode, 1: Host Mode (or dedicated RCC). BIT 1 : Channel SCSI Termination (SCSI Only) (RW) 0: Disabled, 1: Enabled. BIT 2 : SCSI Parity (SCSI Only) (RW) 0: Disabled, 1: Enabled. BIT 3 : Support LUN > 0 (RW) 0: Disabled, 1: Enabled. BIT 8 : Supports Redundant Channel Communication (RO) 0: Does NOT support, 1: Does support. BIT 9 : Redundant Controller Communication Enable (RW) Note that if RCC is enabled on host-mode channels, then the channel is a dedicated RCC channel. If it is enabled on drive-mode channels, then RCC transactions are multiplexed with standard drive-side IOs on the channel. 0: Disabled, 1: Enabled. BIT 12 : 'Shelf' Status Input (SCSI Only) (RW) 0: Disabled, 1: Enabled. BIT 13 : 'Swap' Status Input (SCSI Only) (RW) 0: Disabled, 1: Enabled. BIT 14 : 'Drive Failure' Status Output (SCSI Only) (RW) 0: Disabled, 1: Enabled. BIT 15 : Reserved.

What is chlMode?

A read-write bitmask of channel behavior: bit 0 selects Drive Mode vs. Host Mode (or dedicated redundant-controller-communication), bit 1 toggles SCSI termination, bit 2 toggles SCSI parity, bit 3 enables LUN>0 support, and bit 9 enables redundant-controller communication (RCC) on this channel. Admins set this when reconfiguring a channel's role, e.g. switching a channel from drive-side to host-side use.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1714.1.7.1.8
snmpwalk -v2c -c public <target> IFT-SNMP-MIB::chlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1714.1.7.1.8.1
snmpget -v2c -c public <target> IFT-SNMP-MIB::chlMode.1

Start monitoring Infortrend EonStor/ESDS RAID storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IFT-SNMP-MIB::chlMode OID value, configure state conditions and alerts, and monitor any Infortrend EonStor/ESDS RAID storage controller from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1714infortrendIFT-SNMP-MIB
1.3.6.1.4.1.1714.1extInterfaceIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.7chlTableIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.7.1chlEntryIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.7.1.8chlModeIFT-SNMP-MIB