IFT-SNMP-MIB :: cacheModeFlags

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › IFT-SNMP-MIB › cacheModeFlags

cacheModeFlags

Module: IFT-SNMP-MIB

OID (symbolic): IFT-SNMP-MIB::cacheModeFlags

OID (numeric): 1.3.6.1.4.1.1714.1.1.2.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Caching mode flags BIT 0 : Write Back Status (RW) 0: Disabled, 1: Enabled. BIT 1 : Read Ahead Disable (RW) 0: Enabled, 1: Disabled. BIT 2 : Enable/Disable keeping LD/LV off-line after controller initialization if cached write data was lost (RW) 0: Disabled, 1: Enabled. BIT 3 -- BIT 7 : Reserved (Set to 0). BIT 8 : Cache Optimization Option (RW) 0: Small/Random I/Os, 1: Large/Sequential I/Os BIT 9 -- BIT 15 : Reserved (Set to 0). BIT 16 -- BIT 18 : Periodic Cache Sync Period (RW) For interpretation of values, reference 'Periodic Cache Sync Period Value Cross-Reference List'. BIT 19 -- BIT 21 : Cache Flush Initiation Threshold (RW) For interpretation of values, reference 'Cache Flush Initiation Threshold Valid Cross-Reference List'. BIT 22 -- BIT 25 : Cache Flush Termination Threshold (RW) For interpretation of values, reference 'Cache Flush Termination Threshold Valid Cross-Reference List'. BIT 26 -- BIT 31 : Reserved (Set to 0).

What is cacheModeFlags?

A read-only bitmask summarizing caching behavior: bit 0 shows write-back cache status, bit 1 shows whether read-ahead is disabled, and bits 16-25 encode the periodic cache-sync period and the cache flush initiation/termination thresholds. An admin reads this to confirm whether the array is currently caching writes (faster but riskier on power loss) or running write-through.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1714.1.1.2.1
snmpwalk -v2c -c public <target> IFT-SNMP-MIB::cacheModeFlags

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1714.1.1.2.1.1
snmpget -v2c -c public <target> IFT-SNMP-MIB::cacheModeFlags.1

Start monitoring Infortrend EonStor/ESDS RAID storage controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IFT-SNMP-MIB::cacheModeFlags OID value, configure state conditions and alerts, and monitor any Infortrend EonStor/ESDS RAID storage controller from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1714infortrendIFT-SNMP-MIB
1.3.6.1.4.1.1714.1extInterfaceIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.1ctlrConfigurationIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.1.2cachingParamsIFT-SNMP-MIB
1.3.6.1.4.1.1714.1.1.2.1cacheModeFlagsIFT-SNMP-MIB