All MIBs › IEEE8021X-PAE-MIB › ieee8021XSuppPaeFailed
ieee8021XSuppPaeFailed
Module: IEEE8021X-PAE-MIB
OID (symbolic): IEEE8021X-PAE-MIB::ieee8021XSuppPaeFailed
OID (numeric): 1.3.111.2.802.1.1.15.1.4.1.1.3
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: This object will be set 'true' by PACP if the authentication has failed or has been terminated. The cause could be a failure returned by EAP, either immediately or following a reauthentication, an excessive number of attempts to authenticate (either immediately or upon reauthentication), or the supplicant deasserting authenticate, the object ieee8021XSuppPaeAuthenticate in the same row is 'false'. The PACP will set the object ieee8021XSuppPaeAuthenticated false as well as setting the object 'true'.
What is ieee8021XSuppPaeFailed?
Read-only flag set true when this port's Supplicant authentication has failed or terminated, whether from an EAP failure, hitting the retry limit, or the supplicant deasserting ieee8021XSuppPaeAuthenticate; useful for alerting when a device can't authenticate upstream.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.111.2.802.1.1.15.1.4.1.1.3 snmpwalk -v2c -c public <target> IEEE8021X-PAE-MIB::ieee8021XSuppPaeFailed
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.111.2.802.1.1.15.1.4.1.1.3.1 snmpget -v2c -c public <target> IEEE8021X-PAE-MIB::ieee8021XSuppPaeFailed.1
Start monitoring Vendor-neutral IEEE 802.1X-2010 standard (enterprise access switch/wireless controller, PAE/MKA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IEEE8021X-PAE-MIB::ieee8021XSuppPaeFailed OID value, configure state conditions and alerts, and monitor any Vendor-neutral IEEE 802.1X-2010 standard (enterprise access switch/wireless controller, PAE/MKA) from a single console.
OID Breakdown
Upper-level ancestors (3 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.111.2.802.1.1 | ieee802dot1mibs | IEEE8021-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.111.2.802.1.1.15 | ieee8021XPaeMIB | IEEE8021X-PAE-MIB |
| 1.3.111.2.802.1.1.15.1 | ieee8021XPaeMIBObjects | IEEE8021X-PAE-MIB |
| 1.3.111.2.802.1.1.15.1.4 | ieee8021XPaeSupplicant | IEEE8021X-PAE-MIB |
| 1.3.111.2.802.1.1.15.1.4.1 | ieee8021XSupplicantTable | IEEE8021X-PAE-MIB |
| 1.3.111.2.802.1.1.15.1.4.1.1 | ieee8021XSupplicantEntry | IEEE8021X-PAE-MIB |
| 1.3.111.2.802.1.1.15.1.4.1.1.3 | ieee8021XSuppPaeFailed | IEEE8021X-PAE-MIB |