IEC-62439-3-MIB :: lreCntTxA

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › IEC-62439-3-MIB › lreCntTxA

lreCntTxA

Module: IEC-62439-3-MIB

OID (symbolic): IEC-62439-3-MIB::lreCntTxA

OID (numeric): 1.0.62439.2.21.1.1.0.1.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: number of frames sent over port A that are HSR tagged or fitted with a PRP Redundancy Control Trailer. Only frames that are HSR tagged or do have a PRP RCT are counted. A frame aborted during the transmission is not counted. Initial value = 0.

What is lreCntTxA?

This Counter32 counts frames sent over LRE port A that carry an HSR tag or PRP Redundancy Control Trailer, not counting frames aborted mid-transmission. Admins use it to confirm port A is actively transmitting redundancy-tagged traffic as expected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.0.62439.2.21.1.1.0.1.1.2
snmpwalk -v2c -c public <target> IEC-62439-3-MIB::lreCntTxA

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.0.62439.2.21.1.1.0.1.1.2.1
snmpget -v2c -c public <target> IEC-62439-3-MIB::lreCntTxA.1

Start monitoring Vendor-neutral industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IEC-62439-3-MIB::lreCntTxA OID value, configure state conditions and alerts, and monitor any Vendor-neutral industrial Ethernet switches from a single console.

How to Use in IPNetwork Monitor

Select a device implementing IEC-62439-3-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type lreCntTxA into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports number of frames sent over port A that are HSR tagged or fitted with a PRP Redundancy Control Trailer. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (2 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.0stdSTART-MIB
Numeric OIDNameModule
1.0.62439iec62439IEC-62439-3-MIB
1.0.62439.2prpIEC-62439-3-MIB
1.0.62439.2.21linkRedundancyEntityObjectsIEC-62439-3-MIB
1.0.62439.2.21.1lreStatisticsIEC-62439-3-MIB
1.0.62439.2.21.1.1lreStatisticsInterfaceGroupIEC-62439-3-MIB
1.0.62439.2.21.1.1.0lreStatisticsInterfacesIEC-62439-3-MIB
1.0.62439.2.21.1.1.0.1lreInterfaceStatsTableIEC-62439-3-MIB
1.0.62439.2.21.1.1.0.1.1lreInterfaceStatsEntryIEC-62439-3-MIB
1.0.62439.2.21.1.1.0.1.1.2lreCntTxAIEC-62439-3-MIB