All MIBs › IBM-TN3270E-MIB › ibmtn3270eConnRejectReason
ibmtn3270eConnRejectReason
Module: IBM-TN3270E-MIB
OID (symbolic): IBM-TN3270E-MIB::ibmtn3270eConnRejectReason
OID (numeric): 1.3.6.1.4.1.2.6.119.4.18.1.1.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The reason the connection was rejected. Some of the values sound similar, but represent different failure points within the TN3270E server software. Also, some values are very specific to the TN3270E server software internals, so they may seem a bit cryptic to the user.
noportinfo (1) // GetPortInfo failed to retrieve Port information cliunknown (2) // HostName filter failure - client_hostname unknown clinoauth (3) // Client is not authorized by FilterUser sockblock (4) // Could not make socket nonblocking nodeterm (5) // Node is terminating createfail (6) // TN3270Create failed to create session environment seqnum (7) // 0xFF seq number not doubled negfailed (8) // Negotiation failed notelquale (9) // Not TELQUALE_REQUEST termtypefail (10) // Verification of terminal type failed notypeprtgen (11) // TELQUALE_ASSOCIATE req but not TYPE_PRINTER_GENERIC clirplyfail (12) // Sending reply to client failed. valtelquale (13) // Validation of TELQUALE_REQUEST failed clisendfail (14) // Send to client failed failtelquale (15) // Verification of TELQUAL_IS failed termtypagain (16) // Received invalid terminal type for 2nd time noportagain (17) // GetPortInfo failed to retrieve Port information prtnoluname (18) // Associated printer req. with no LU name specified clinoauthent (19) // Client is not authorized by Filter entries clinoauthflt (20) // Client not authorized by Filter entries after retry noluconf (21) // REJECT_UNSUPP_REQ: No LUs configured. noportmore (22) // GetPortInfo failed to retrieve Port information noresource (23) // No resource spe+cified on Port & no name requested nameresource (24) // Resource specified on Port doesn't match name requested prtnoluagain (25) // Associated printer req. with no LU name specified noimplu (26) // No implicit LUs are available lunotfound (27) // Specified LU not found/available valluprt (28) // Validation of LU type failed for assoc. printer vallu (29) // Validation of LU type failed prtlunofind (30) // LU for associated printer not found nameinuse (31) // LU name requested currently in use reqlunofind (32) // LU requested not found valprtagain (33) // Validation of LU type failed for assoc. printer valluagain (34) // Validation of LU type failed luprtnofind (35) // LU for associated printer not found poolluinuse (36) // Requested pooled LU is already in use poollunofind (37) // Requested pooled LU is not found for assoc. printer restypnofind (38) // Requested type of resource is not found poolluconf (39) // Requested pooled LU is not found in config. list lucapreach (40) // LU capping value reached for this client address noappnmem (41) // APPN memory above the constrained threashold nomoreconn (42) // Max. number of TN3270 connection reached pooldep (43) // The pool from which the resource was requested has been depleted termnorsp (44) // The session was terminated before receiving a response from APPN
What is ibmtn3270eConnRejectReason?
This value reports a specific internal reason code explaining exactly why a TN3270E connection attempt was rejected by the server, covering a wide range of causes from client filtering and authorization failures to LU, or logical unit, resource exhaustion or negotiation failures. Administrators and IBM support staff use it to pinpoint precisely where in the TN3270E server's internal processing a connection attempt failed, since the codes are detailed enough to distinguish between many related but distinct failure points. For example, a code of noimplu(26) would tell the admin the rejection happened specifically because no implicit LU was available to assign the client, rather than a more general authentication failure.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.6.119.4.18.1.1.1.4 snmpwalk -v2c -c public <target> IBM-TN3270E-MIB::ibmtn3270eConnRejectReason
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2.6.119.4.18.1.1.1.4.1 snmpget -v2c -c public <target> IBM-TN3270E-MIB::ibmtn3270eConnRejectReason.1
Start monitoring IBM TN3270E server (SNA/mainframe terminal-emulation gateway) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IBM-TN3270E-MIB::ibmtn3270eConnRejectReason OID value, configure state conditions and alerts, and monitor any IBM TN3270E server (SNA/mainframe terminal-emulation gateway) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2 | ibm | ATM-ADAPTER-MIB |
| 1.3.6.1.4.1.2.6 | ibmProd | ATM-ADAPTER-MIB |
| 1.3.6.1.4.1.2.6.119 | ibmIROC | IBMIROCDIALOUT-MIB |
| 1.3.6.1.4.1.2.6.119.4 | ibmIROCrouting | IBMIROCDIALOUT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2.6.119.4.18.1 | ibmtn3270eMIB | IBM-TN3270E-MIB |
| 1.3.6.1.4.1.2.6.119.4.18.1.1 | ibmtn3270eConnRejectTable | IBM-TN3270E-MIB |
| 1.3.6.1.4.1.2.6.119.4.18.1.1.1 | ibmtn3270eConnRejectEntry | IBM-TN3270E-MIB |
| 1.3.6.1.4.1.2.6.119.4.18.1.1.1.4 | ibmtn3270eConnRejectReason | IBM-TN3270E-MIB |