HUAWEI-VOICEPORT-MIB :: hwPstnPTPCurrent

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHUAWEI-VOICEPORT-MIBhwPstnPTPCurrent

hwPstnPTPCurrent

Module: HUAWEI-VOICEPORT-MIB

OID (symbolic): HUAWEI-VOICEPORT-MIB::hwPstnPTPCurrent

OID (numeric): 1.3.6.1.4.1.2011.6.113.1.1.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Port current supported by the board. The value ranges from 1 to 19, which indicates the port current value supported under certain loopline impedence. 1 -- 25mA steady current 2 -- 16mA steady current 3 -- 32mA steady current 4 -- 40mA steady current 5 -- 35mA 2*200 ohm 6 -- 35mA 2*250 ohm 7 -- 35mA 2*400 ohm 8 -- 47mA 2*200 ohm 9 -- 47mA 2*250 ohm 10 -- 47mA 2*400 ohm 11 -- 20mA 2*200 ohm 12 -- 20mA 2*250 ohm 13 -- 20mA 2*400 ohm 14 -- 30mA 2*200 ohm 15 -- 30mA 2*250 ohm 16 -- 30mA 2*400 ohm 17 -- 40mA 2*200 ohm 18 -- 40mA 2*250 ohm 19 -- 40mA 2*400 ohm

What is hwPstnPTPCurrent?

This sets the loop current the port supplies to the analog line, as a code from 1 to 19 mapping to specific current/resistance combinations (e.g. 3 = 32mA steady current, 10 = 47mA at 2x400 ohm, the default). Admins adjust this to match cable length and connected phone equipment so the line has enough current to operate reliably without exceeding the port's rated output.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.6.113.1.1.1.9
snmpwalk -v2c -c public <target> HUAWEI-VOICEPORT-MIB::hwPstnPTPCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.6.113.1.1.1.9.1
snmpget -v2c -c public <target> HUAWEI-VOICEPORT-MIB::hwPstnPTPCurrent.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.6.113.1.1.1.9.1 i <value>

Start monitoring Huawei voice gateway/integrated access device (physical voice port parameters) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-VOICEPORT-MIB::hwPstnPTPCurrent OID value, configure state conditions and alerts, and monitor any Huawei voice gateway/integrated access device (physical voice port parameters) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.113hwIASVoicePortHUAWEI-VOICEPORT-MIB
1.3.6.1.4.1.2011.6.113.1hwIASVoicePortObjectsHUAWEI-VOICEPORT-MIB
1.3.6.1.4.1.2011.6.113.1.1hwPstnPTPConfigTableHUAWEI-VOICEPORT-MIB
1.3.6.1.4.1.2011.6.113.1.1.1hwPstnPTPConfigEntryHUAWEI-VOICEPORT-MIB
1.3.6.1.4.1.2011.6.113.1.1.1.9hwPstnPTPCurrentHUAWEI-VOICEPORT-MIB