HUAWEI-IMA-MIB :: hwImaGroupNumTxActLinks

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-IMA-MIB › hwImaGroupNumTxActLinks

hwImaGroupNumTxActLinks

Module: HUAWEI-IMA-MIB

OID (symbolic): HUAWEI-IMA-MIB::hwImaGroupNumTxActLinks

OID (numeric): 1.3.6.1.4.1.2011.5.25.176.1.1.1.17

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The number of links which are configured to transmit and are currently Active in this IMA group.

What is hwImaGroupNumTxActLinks?

Reports how many of the links configured for transmit in this IMA group are currently Active, letting an admin quickly see if the bundle is running at full capacity or has lost member links.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.5.25.176.1.1.1.17
snmpwalk -v2c -c public <target> HUAWEI-IMA-MIB::hwImaGroupNumTxActLinks

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.5.25.176.1.1.1.17.1
snmpget -v2c -c public <target> HUAWEI-IMA-MIB::hwImaGroupNumTxActLinks.1

Start monitoring Huawei router/access device with ATM IMA (Inverse Multiplexing for ATM) interfaces with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-IMA-MIB::hwImaGroupNumTxActLinks OID value, configure state conditions and alerts, and monitor any Huawei router/access device with ATM IMA (Inverse Multiplexing for ATM) interfaces from a single console.

How to Use in IPNetwork Monitor

Select a Huawei router/access device with ATM IMA (Inverse Multiplexing for ATM) interface as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hwImaGroupNumTxActLinks into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of links which are configured to transmit and are currently Active in this IMA group. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.5huaweiMgmtHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.5.25huaweiDatacommHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.5.25.176hwImaMIBHUAWEI-IMA-MIB
1.3.6.1.4.1.2011.5.25.176.1hwImaMibObjectsHUAWEI-IMA-MIB
1.3.6.1.4.1.2011.5.25.176.1.1hwImaGroupTableHUAWEI-IMA-MIB
1.3.6.1.4.1.2011.5.25.176.1.1.1hwImaGroupEntryHUAWEI-IMA-MIB
1.3.6.1.4.1.2011.5.25.176.1.1.1.17hwImaGroupNumTxActLinksHUAWEI-IMA-MIB