HUAWEI-CLK-MIB :: hwClkOutPriority

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-CLK-MIB › hwClkOutPriority

hwClkOutPriority

Module: HUAWEI-CLK-MIB

OID (symbolic): HUAWEI-CLK-MIB::hwClkOutPriority

OID (numeric): 1.3.6.1.4.1.2011.6.25.1.2.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Clock source priority, 0 is the highest priority and from 0 to 9 priority is descending If get value is 255, it indicates that the priority of the clock souce isn't configured.

What is hwClkOutPriority?

This read-write integer sets the selection priority of a clock source for a given clock output, where 0 is the highest priority and priority descends from 0 to 9; a read value of 255 means no priority has been configured. Admins tune these priorities across multiple clock-input entries to control which source the device falls back to first if the primary timing reference fails. For example, setting hwClkOutPriority to 0 on the sdh output for a given input makes that source the device's first choice for SDH clock recovery.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.6.25.1.2.1.3
snmpwalk -v2c -c public <target> HUAWEI-CLK-MIB::hwClkOutPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.6.25.1.2.1.3.1
snmpget -v2c -c public <target> HUAWEI-CLK-MIB::hwClkOutPriority.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.6.25.1.2.1.3.1 i <value>

Start monitoring Huawei carrier-grade router/switch with clock synchronization boards with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-CLK-MIB::hwClkOutPriority OID value, configure state conditions and alerts, and monitor any Huawei carrier-grade router/switch with clock synchronization boards from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.25hwClockHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1hwClkMibObjectsHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1.2hwClockOutManageTableHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1.2.1hwClockOutManageEntryHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1.2.1.3hwClkOutPriorityHUAWEI-CLK-MIB