hwClkInRowStatus

Module: HUAWEI-CLK-MIB

OID (symbolic): HUAWEI-CLK-MIB::hwClkInRowStatus

OID (numeric): 1.3.6.1.4.1.2011.6.25.1.1.1.5

Node type: OBJECT-TYPE

Type: RowStatus

Access: read-create

Description: Clock Source operation add clock source and clear clock source by user. when a user adds clock source, clock works in trace mode and when a user clears clock source clock works in srystal mode. To set position(frame,slot,port) and oper(4), these two operation should be set together. oper(6) could be set by itself. To set a bit clock source, the frame,slot,port parameters are useless. Oper(6) is used to clear a clock source.

What is hwClkInRowStatus?

This read-create RowStatus value governs adding and clearing clock-source entries in the clock-input management table: adding a source puts the clock in trace mode, while clearing it reverts to crystal mode, and the position/oper fields must be set together for certain operations. Admins use it to provision or remove a physical or logical clock source entry from the device's timing configuration. For example, an admin configuring a new BITS clock source would set hwClkInRowStatus alongside the frame/slot/port fields to add that entry to the table.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.25hwClockHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1hwClkMibObjectsHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1.1hwClockInManageTableHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1.1.1hwClockInManageEntryHUAWEI-CLK-MIB
1.3.6.1.4.1.2011.6.25.1.1.1.5hwClkInRowStatusHUAWEI-CLK-MIB