HPROD-SNMP-RPI-MIB :: hPsnmpRpiCpuTemp

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › HPROD-SNMP-RPI-MIB › hPsnmpRpiCpuTemp

hPsnmpRpiCpuTemp

Module: HPROD-SNMP-RPI-MIB

OID (symbolic): HPROD-SNMP-RPI-MIB::hPsnmpRpiCpuTemp

OID (numeric): 1.3.6.1.4.1.44776.1.3.1.1

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Hedberg productions SNMP RPI Cpu Temperature.

What is hPsnmpRpiCpuTemp?

This object reports the current CPU temperature reading from the device, as exposed by a hobbyist SNMP agent for Raspberry Pi boards. An admin polls it to keep an eye on thermal conditions on small embedded or single-board devices that lack more elaborate hardware-monitoring MIBs. A healthy reading might come back around 45 (degrees Celsius), while a value climbing past 70 would suggest the board needs better cooling or airflow.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.44776.1.3.1.1
snmpwalk -v2c -c public <target> HPROD-SNMP-RPI-MIB::hPsnmpRpiCpuTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.44776.1.3.1.1.1
snmpget -v2c -c public <target> HPROD-SNMP-RPI-MIB::hPsnmpRpiCpuTemp.1

Start monitoring Raspberry Pi device (Hedberg Productions SNMP agent) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPROD-SNMP-RPI-MIB::hPsnmpRpiCpuTemp OID value, configure state conditions and alerts, and monitor any Raspberry Pi device (Hedberg Productions SNMP agent) from a single console.

How to Use in IPNetwork Monitor

Select a Raspberry Pi device (Hedberg Productions SNMP agent) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hPsnmpRpiCpuTemp into the Find box to locate it in the OID tree, then select it and click OK. It reports the hedberg productions SNMP RPI Cpu Temperature. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.44776hedbergProductionsHPROD-SNMP-MIB
1.3.6.1.4.1.44776.1hPsnmpRootHPROD-SNMP-MIB
1.3.6.1.4.1.44776.1.3hPsnmpMIBSHPROD-SNMP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.44776.1.3.1hPsnmpRpiRootHPROD-SNMP-RPI-MIB
1.3.6.1.4.1.44776.1.3.1.1hPsnmpRpiCpuTempHPROD-SNMP-RPI-MIB