HPN-ICF-SMLK-MIB :: hpnicfSmlkFlushCount

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › HPN-ICF-SMLK-MIB › hpnicfSmlkFlushCount

hpnicfSmlkFlushCount

Module: HPN-ICF-SMLK-MIB

OID (symbolic): HPN-ICF-SMLK-MIB::hpnicfSmlkFlushCount

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.147.1.2.1.4

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Number of transmitted flush messages.

What is hpnicfSmlkFlushCount?

This read-only Counter64 value counts the number of flush messages transmitted by a port in a Smart Link group. An admin monitors this counter to see how often MAC-address-flush notifications have been sent after failover events, which helps gauge link stability. A flush count that jumps from 5 to 6 indicates one more failover-triggered flush message was sent on that port since the last poll.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.147.1.2.1.4
snmpwalk -v2c -c public <target> HPN-ICF-SMLK-MIB::hpnicfSmlkFlushCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.147.1.2.1.4.1
snmpget -v2c -c public <target> HPN-ICF-SMLK-MIB::hpnicfSmlkFlushCount.1

Start monitoring HPE/H3C Comware access/aggregation switch, dual-uplink (Smart Link redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-SMLK-MIB::hpnicfSmlkFlushCount OID value, configure state conditions and alerts, and monitor any HPE/H3C Comware access/aggregation switch, dual-uplink (Smart Link redundancy) from a single console.

How to Use in IPNetwork Monitor

Select an HPE/H3C Comware access/aggregation switch, dual-uplink (Smart Link redundancy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpnicfSmlkFlushCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of transmitted flush messages. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.147hpnicfSmlkHPN-ICF-SMLK-MIB
1.3.6.1.4.1.11.2.14.11.15.2.147.1hpnicfSmlkObjectHPN-ICF-SMLK-MIB
1.3.6.1.4.1.11.2.14.11.15.2.147.1.2hpnicfSmlkPortTableHPN-ICF-SMLK-MIB
1.3.6.1.4.1.11.2.14.11.15.2.147.1.2.1hpnicfSmlkPortEntryHPN-ICF-SMLK-MIB
1.3.6.1.4.1.11.2.14.11.15.2.147.1.2.1.4hpnicfSmlkFlushCountHPN-ICF-SMLK-MIB