HPN-ICF-CATV-TRANSCEIVER-MIB :: hpnicfCATVTransInputPwrLowerThr

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HPN-ICF-CATV-TRANSCEIVER-MIB › hpnicfCATVTransInputPwrLowerThr

hpnicfCATVTransInputPwrLowerThr

Module: HPN-ICF-CATV-TRANSCEIVER-MIB

OID (symbolic): HPN-ICF-CATV-TRANSCEIVER-MIB::hpnicfCATVTransInputPwrLowerThr

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.94.2.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: A threshold for the CATV transceiver's input power. When the input power of CATV transceiver is lower than threshold, a trap should be generated.

What is hpnicfCATVTransInputPwrLowerThr?

This read-write Integer32, in dBm, sets the low-power alarm threshold for the CATV transceiver's input signal, and per the description a trap is generated when hpnicfCATVTransInputPwr drops below this configured value. An admin tunes this threshold to match acceptable signal levels for their CATV plant so they're alerted before a weak signal causes service degradation. For example, setting this to -20 dBm would trigger an alarm trap if the measured input power falls below that level.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.94.2.1.1
snmpwalk -v2c -c public <target> HPN-ICF-CATV-TRANSCEIVER-MIB::hpnicfCATVTransInputPwrLowerThr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.94.2.1.1.1
snmpget -v2c -c public <target> HPN-ICF-CATV-TRANSCEIVER-MIB::hpnicfCATVTransInputPwrLowerThr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.94.2.1.1.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hpnicfCATVTransInputPwrLowerThr.1

Start monitoring HP Networking switch with CATV (hybrid fiber-coax) optical transceiver module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-CATV-TRANSCEIVER-MIB::hpnicfCATVTransInputPwrLowerThr OID value, configure state conditions and alerts, and monitor any HP Networking switch with CATV (hybrid fiber-coax) optical transceiver module from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.94hpnicfCATVTransceiverHPN-ICF-CATV-TRANSCEIVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.94.2hpnicfCATVTransceiverManHPN-ICF-CATV-TRANSCEIVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.94.2.1hpnicfCATVTransCtrlScalarObjectsHPN-ICF-CATV-TRANSCEIVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.94.2.1.1hpnicfCATVTransInputPwrLowerThrHPN-ICF-CATV-TRANSCEIVER-MIB