HM2-PLATFORM-SFLOW-MIB :: hm2AgentSflowSourceInterface

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-PLATFORM-SFLOW-MIB › hm2AgentSflowSourceInterface

hm2AgentSflowSourceInterface

Module: HM2-PLATFORM-SFLOW-MIB

OID (symbolic): HM2-PLATFORM-SFLOW-MIB::hm2AgentSflowSourceInterface

OID (numeric): 1.3.6.1.4.1.248.12.59.1.1

Node type: OBJECT-TYPE

Type: InterfaceIndexOrZero

Access: read-write

Description: A source-interface selection on an Interface Index (like vlan based routing interface, port based routing interface, loopback interface, tunnel interface). A non-zero value indicates ifIndex for the corresponding interface entry in the ifTable is selected. A zero value indicates source-interface is un-configured.

What is hm2AgentSflowSourceInterface?

This value picks which interface's IP address the device uses as the source address when sending sFlow sampled-traffic datagrams to a remote sFlow collector, identified by that interface's ifIndex. Admins set it to a stable interface, such as a loopback or VLAN routing interface, so the sFlow collector always sees samples arriving from one consistent source address regardless of which physical port actually captured the traffic. Leaving the value at zero means no source interface has been explicitly configured for sFlow on this HM2 platform device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.12.59.1.1
snmpwalk -v2c -c public <target> HM2-PLATFORM-SFLOW-MIB::hm2AgentSflowSourceInterface

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.12.59.1.1.1
snmpget -v2c -c public <target> HM2-PLATFORM-SFLOW-MIB::hm2AgentSflowSourceInterface.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.12.59.1.1.1 s <value>

Start monitoring Hirschmann HiOS Platform2 industrial switch (sFlow source interface) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-PLATFORM-SFLOW-MIB::hm2AgentSflowSourceInterface OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS Platform2 industrial switch (sFlow source interface) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.12hm2PlatformMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.12.59hm2PlatformSflowHM2-PLATFORM-SFLOW-MIB
1.3.6.1.4.1.248.12.59.1hm2AgentFastPathSflowObjectsHM2-PLATFORM-SFLOW-MIB
1.3.6.1.4.1.248.12.59.1.1hm2AgentSflowSourceInterfaceHM2-PLATFORM-SFLOW-MIB