HILLSTONE-TEMPERATURE-MIB :: hillstoneTemperatureValue

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HILLSTONE-TEMPERATURE-MIB › hillstoneTemperatureValue

hillstoneTemperatureValue

Module: HILLSTONE-TEMPERATURE-MIB

OID (symbolic): HILLSTONE-TEMPERATURE-MIB::hillstoneTemperatureValue

OID (numeric): 1.3.6.1.4.1.28557.2.28.1.2.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The TEMPERATURE value .

What is hillstoneTemperatureValue?

This value reports the current reading from a specific temperature sensor on the device, typically in degrees Celsius. Administrators monitor it to catch overheating conditions before they cause instability or hardware damage, often pairing it with alert thresholds. For example, a reading that climbs from 45 to 75 over a short period could indicate a failing fan or blocked airflow.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.28557.2.28.1.2.1.3
snmpwalk -v2c -c public <target> HILLSTONE-TEMPERATURE-MIB::hillstoneTemperatureValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.28557.2.28.1.2.1.3.1
snmpget -v2c -c public <target> HILLSTONE-TEMPERATURE-MIB::hillstoneTemperatureValue.1

Start monitoring Hillstone Networks firewalls/UTM appliances with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HILLSTONE-TEMPERATURE-MIB::hillstoneTemperatureValue OID value, configure state conditions and alerts, and monitor any Hillstone Networks firewalls/UTM appliances from a single console.

How to Use in IPNetwork Monitor

Select a Hillstone Networks firewalls/UTM appliance as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hillstoneTemperatureValue into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The TEMPERATURE value . On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.28557hillstoneHILLSTONE-SMI
1.3.6.1.4.1.28557.2hillstoneMibsHILLSTONE-SMI
1.3.6.1.4.1.28557.2.28hillstoneTemperatureHILLSTONE-SMI
Numeric OIDNameModule
1.3.6.1.4.1.28557.2.28.1hillstoneTemperatureObjectsHILLSTONE-TEMPERATURE-MIB
1.3.6.1.4.1.28557.2.28.1.2hillstoneTemperatureTableHILLSTONE-TEMPERATURE-MIB
1.3.6.1.4.1.28557.2.28.1.2.1hillstoneTemperatureEntryHILLSTONE-TEMPERATURE-MIB
1.3.6.1.4.1.28557.2.28.1.2.1.3hillstoneTemperatureValueHILLSTONE-TEMPERATURE-MIB