HH3C-WLANMT-MIB :: hh3cWlanMtToCpuTxFrameCnt

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › HH3C-WLANMT-MIB › hh3cWlanMtToCpuTxFrameCnt

hh3cWlanMtToCpuTxFrameCnt

Module: HH3C-WLANMT-MIB

OID (symbolic): HH3C-WLANMT-MIB::hh3cWlanMtToCpuTxFrameCnt

OID (numeric): 1.3.6.1.4.1.25506.2.157.2.1

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total packets send to cpu successfully.

What is hh3cWlanMtToCpuTxFrameCnt?

This 64-bit counter tracks the total number of frames successfully sent up to the device's CPU for processing. Admins use it to confirm that control-plane traffic, such as management or protocol frames destined for the CPU, is actually getting through as expected. A steady, expected rate of increase in hh3cWlanMtToCpuTxFrameCnt confirms the CPU is receiving the frames punted to it by the forwarding hardware.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.157.2.1
snmpwalk -v2c -c public <target> HH3C-WLANMT-MIB::hh3cWlanMtToCpuTxFrameCnt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.157.2.1.1
snmpget -v2c -c public <target> HH3C-WLANMT-MIB::hh3cWlanMtToCpuTxFrameCnt.1

Start monitoring H3C wireless LAN controller/access point (VCPU forwarding-plane performance) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-WLANMT-MIB::hh3cWlanMtToCpuTxFrameCnt OID value, configure state conditions and alerts, and monitor any H3C wireless LAN controller/access point (VCPU forwarding-plane performance) from a single console.

How to Use in IPNetwork Monitor

Select an H3C wireless LAN controller/access point (VCPU forwarding-plane performance) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cWlanMtToCpuTxFrameCnt into the Find box to locate it in the OID tree, then select it and click OK. The total packets send to cpu successfully. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.157hh3cWlanMtHH3C-WLANMT-MIB
1.3.6.1.4.1.25506.2.157.2hh3cWlanMtFrameToCpuHH3C-WLANMT-MIB
1.3.6.1.4.1.25506.2.157.2.1hh3cWlanMtToCpuTxFrameCntHH3C-WLANMT-MIB