HH3C-SMLK-MIB :: hh3cSmlkFlushCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-SMLK-MIB › hh3cSmlkFlushCount

hh3cSmlkFlushCount

Module: HH3C-SMLK-MIB

OID (symbolic): HH3C-SMLK-MIB::hh3cSmlkFlushCount

OID (numeric): 1.3.6.1.4.1.25506.2.147.1.2.1.4

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Number of transmitted flush messages.

What is hh3cSmlkFlushCount?

This counter tracks the total number of flush messages a port has transmitted as part of Smart Link group operation, used to clear stale MAC address table entries after a failover. Admins monitor this counter to confirm that failover events are actually triggering the expected flush notifications to other switches. For example, a sudden jump in hh3cSmlkFlushCount indicates the Smart Link group just switched active ports and notified the network to relearn MAC addresses.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.147.1.2.1.4
snmpwalk -v2c -c public <target> HH3C-SMLK-MIB::hh3cSmlkFlushCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.147.1.2.1.4.1
snmpget -v2c -c public <target> HH3C-SMLK-MIB::hh3cSmlkFlushCount.1

Start monitoring H3C access switch, dual-uplink (Smart Link redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-SMLK-MIB::hh3cSmlkFlushCount OID value, configure state conditions and alerts, and monitor any H3C access switch, dual-uplink (Smart Link redundancy) from a single console.

How to Use in IPNetwork Monitor

Select an H3C access switch, dual-uplink (Smart Link redundancy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cSmlkFlushCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of transmitted flush messages. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.147hh3cSmlkHH3C-SMLK-MIB
1.3.6.1.4.1.25506.2.147.1hh3cSmlkObjectHH3C-SMLK-MIB
1.3.6.1.4.1.25506.2.147.1.2hh3cSmlkPortTableHH3C-SMLK-MIB
1.3.6.1.4.1.25506.2.147.1.2.1hh3cSmlkPortEntryHH3C-SMLK-MIB
1.3.6.1.4.1.25506.2.147.1.2.1.4hh3cSmlkFlushCountHH3C-SMLK-MIB