HH3C-RMON-EXT2-MIB :: hh3cRmonExtAlarmValue

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-RMON-EXT2-MIB › hh3cRmonExtAlarmValue

hh3cRmonExtAlarmValue

Module: HH3C-RMON-EXT2-MIB

OID (symbolic): HH3C-RMON-EXT2-MIB::hh3cRmonExtAlarmValue

OID (numeric): 1.3.6.1.4.1.25506.2.125.1.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value will be the sampled value at the end of the period. This is the value that is compared with the rising and falling thresholds.

The value during the current sampling period is not made available until the period is completed and will remain available until the next period completes.

What is hh3cRmonExtAlarmValue?

This read-only field reports the computed statistic from the most recently completed sampling period - the delta or absolute value depending on the sample type - which is the number actually compared to the rising and falling thresholds. Because it isn't updated until a full interval completes, admins polling this value are always seeing the last finished period's result, not a live in-progress figure. If the falling threshold is 0 and this value reads 5 after the latest interval, the alarm condition hasn't yet been triggered for that entry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.125.1.1.6
snmpwalk -v2c -c public <target> HH3C-RMON-EXT2-MIB::hh3cRmonExtAlarmValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.125.1.1.6.1
snmpget -v2c -c public <target> HH3C-RMON-EXT2-MIB::hh3cRmonExtAlarmValue.1

Start monitoring H3C networking equipment (extended RMON threshold alarms) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-RMON-EXT2-MIB::hh3cRmonExtAlarmValue OID value, configure state conditions and alerts, and monitor any H3C networking equipment (extended RMON threshold alarms) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.125hh3cRmonExtHH3C-RMON-EXT2-MIB
1.3.6.1.4.1.25506.2.125.1hh3cRmonExtAlarmTableHH3C-RMON-EXT2-MIB
1.3.6.1.4.1.25506.2.125.1.1hh3cRmonExtAlarmEntryHH3C-RMON-EXT2-MIB
1.3.6.1.4.1.25506.2.125.1.1.6hh3cRmonExtAlarmValueHH3C-RMON-EXT2-MIB