All MIBs › HH3C-REDUNDANCY-POWER-MIB › hh3credundancyPowerStatus
hh3credundancyPowerStatus
Module: HH3C-REDUNDANCY-POWER-MIB
OID (symbolic): HH3C-REDUNDANCY-POWER-MIB::hh3credundancyPowerStatus
OID (numeric): 1.3.6.1.4.1.25506.8.36.4.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail'
What is hh3credundancyPowerStatus?
This value reports the current health of a specific redundant power supply unit -- whether that power slot is empty (space), populated and working normally, or populated but faulted. Administrators monitor this to catch power supply failures in a redundant configuration before they become a single point of failure if the other unit also fails. For example, a value of fail(3) for one power unit while the other reads normal(2) would tell an admin the chassis is currently running on only one functioning power supply and the faulted unit needs replacing.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.8.36.4.1.1.2 snmpwalk -v2c -c public <target> HH3C-REDUNDANCY-POWER-MIB::hh3credundancyPowerStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.8.36.4.1.1.2.1 snmpget -v2c -c public <target> HH3C-REDUNDANCY-POWER-MIB::hh3credundancyPowerStatus.1
Start monitoring H3C modular switch/router with redundant PSU and fan modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-REDUNDANCY-POWER-MIB::hh3credundancyPowerStatus OID value, configure state conditions and alerts, and monitor any H3C modular switch/router with redundant PSU and fan modules from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.25506 | hh3c | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8 | hh3cRhw | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8.36 | hh3cmlsr | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8.36.4 | hh3credundancyPower | HH3C-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25506.8.36.4.1 | hh3credundancyPowerTable | HH3C-REDUNDANCY-POWER-MIB |
| 1.3.6.1.4.1.25506.8.36.4.1.1 | hh3credundancyPowerEntry | HH3C-REDUNDANCY-POWER-MIB |
| 1.3.6.1.4.1.25506.8.36.4.1.1.2 | hh3credundancyPowerStatus | HH3C-REDUNDANCY-POWER-MIB |