All MIBs › HH3C-REDUNDANCY-POWER-MIB › hh3credundancyFanStatus
hh3credundancyFanStatus
Module: HH3C-REDUNDANCY-POWER-MIB
OID (symbolic): HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanStatus
OID (numeric): 1.3.6.1.4.1.25506.8.36.5.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail'
What is hh3credundancyFanStatus?
This value reports whether a specific redundant cooling fan is currently operating normally or has failed; note that although the device's own MIB description text (evidently copy-pasted from the power-unit status object) mentions a third 'space' state, the actual defined syntax for this fan-status object only supports normal(1) or fail(2). Administrators monitor this to detect a failed cooling fan in a redundant fan tray before it leads to a thermal issue, especially if the other fan also degrades. For example, a value of fail(2) on one fan unit while its cooling partner reads normal(1) would prompt an admin to schedule replacement of the failed fan before overall cooling capacity is compromised.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.8.36.5.1.1.2 snmpwalk -v2c -c public <target> HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.8.36.5.1.1.2.1 snmpget -v2c -c public <target> HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanStatus.1
Start monitoring H3C modular switch/router with redundant PSU and fan modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanStatus OID value, configure state conditions and alerts, and monitor any H3C modular switch/router with redundant PSU and fan modules from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.25506 | hh3c | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8 | hh3cRhw | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8.36 | hh3cmlsr | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8.36.5 | hh3credundancyFan | HH3C-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25506.8.36.5.1 | hh3credundancyFanTable | HH3C-REDUNDANCY-POWER-MIB |
| 1.3.6.1.4.1.25506.8.36.5.1.1 | hh3credundancyFanEntry | HH3C-REDUNDANCY-POWER-MIB |