Description: The identify of power uinit. This is also the index of this table.
What is hh3credundancyFanID?
This value identifies which specific redundant cooling fan, among potentially several in the chassis, a given fan-status table row describes -- note that the source MIB's own description text mistakenly still refers to it as a 'power unit,' apparently copy-pasted from the power supply table. Administrators use this index to know exactly which fan unit a status entry pertains to when reviewing chassis cooling health. For example, this value might read 1, identifying the first of the chassis's redundant fan units.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.8.36.5.1.1.1 snmpwalk -v2c -c public <target> HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanID
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.8.36.5.1.1.1.1 snmpget -v2c -c public <target> HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanID.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hh3credundancyFanID.1
Start monitoring H3C modular switch/router with redundant PSU and fan modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-REDUNDANCY-POWER-MIB::hh3credundancyFanID OID value, configure state conditions and alerts, and monitor any H3C modular switch/router with redundant PSU and fan modules from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.25506 | hh3c | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8 | hh3cRhw | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8.36 | hh3cmlsr | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.8.36.5 | hh3credundancyFan | HH3C-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25506.8.36.5.1 | hh3credundancyFanTable | HH3C-REDUNDANCY-POWER-MIB |
| 1.3.6.1.4.1.25506.8.36.5.1.1 | hh3credundancyFanEntry | HH3C-REDUNDANCY-POWER-MIB |
| 1.3.6.1.4.1.25506.8.36.5.1.1.1 | hh3credundancyFanID | HH3C-REDUNDANCY-POWER-MIB |