All MIBs › HC-ALARM-MIB › hcAlarmFallingThreshAbsValueLo
hcAlarmFallingThreshAbsValueLo
Module: HC-ALARM-MIB
OID (symbolic): HC-ALARM-MIB::hcAlarmFallingThreshAbsValueLo
OID (numeric): 1.3.6.1.2.1.16.29.1.1.1.1.11
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-create
Description: The lower 32 bits of the absolute value for threshold for the sampled statistic. The actual threshold value is determined by the associated instances of the hcAlarmFallingThreshAbsValueHi and hcAlarmFallingThresholdValStatus objects, as follows:
ABS(threshold) = hcAlarmFallingThreshAbsValueLo + (hcAlarmFallingThreshAbsValueHi * 2^^32)
The absolute value of the threshold is adjusted as required, as described in the HcValueStatus textual convention. These three object instances are conceptually combined to represent the falling threshold for this entry.
When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated hcAlarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3).
After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the threshold identified by the hcAlarmRisingThreshAbsValueLo, hcAlarmRisingThreshAbsValueHi, and hcAlarmRisingThresholdValStatus objects.
This object may not be modified if the associated hcAlarmStatus object is equal to active(1).
What is hcAlarmFallingThreshAbsValueLo?
This is the lower 32 bits of the 64-bit absolute falling-threshold value used to detect when a sampled variable drops back down. Admins configure it together with its high-order and sign-status companions to define the point below which a falling alarm event fires, resetting the rising-alarm hysteresis. Setting the low value to 500 defines a falling threshold of 500 units, so a counter that tripped the rising alarm can trigger it again on a future rise only after dropping under that value.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.16 | rmon | ITOUCHHUB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.16.29 | hcAlarmMIB | HC-ALARM-MIB |
| 1.3.6.1.2.1.16.29.1 | hcAlarmObjects | HC-ALARM-MIB |
| 1.3.6.1.2.1.16.29.1.1 | hcAlarmControlObjects | HC-ALARM-MIB |
| 1.3.6.1.2.1.16.29.1.1.1 | hcAlarmTable | HC-ALARM-MIB |
| 1.3.6.1.2.1.16.29.1.1.1.1 | hcAlarmEntry | HC-ALARM-MIB |
| 1.3.6.1.2.1.16.29.1.1.1.1.11 | hcAlarmFallingThreshAbsValueLo | HC-ALARM-MIB |