H3C-SMLK-MIB :: h3cSmlkControlVlanListHigh

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › H3C-SMLK-MIB › h3cSmlkControlVlanListHigh

h3cSmlkControlVlanListHigh

Module: H3C-SMLK-MIB

OID (symbolic): H3C-SMLK-MIB::h3cSmlkControlVlanListHigh

OID (numeric): 1.3.6.1.4.1.2011.10.2.147.1.3.1.3

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Specifies the control VLANs used for receiving flush messages. The VLAN ID range, described by bitmap, is from 2049 to 4094. The length of bitmap is 256 in bytes. Each octet within this value specifies a set of eight VLANs, with the first octet specifying VLANs 2049 through 2056, the second octet specifying VLANs 2057 through 2064, and so on. Within each octet, the most significant bit represents the highest numbered VLAN, and the least significant bit represents the lowest numbered VLAN.

What is h3cSmlkControlVlanListHigh?

This object is a 256-byte bitmap specifying which control VLANs, numbered 2049 through 4094, this interface is enabled to receive Smart Link flush messages on. Admins configure this alongside the low-range object when their control VLANs fall in the upper half of the VLAN ID space. Setting the corresponding bit for VLAN 2049 enables this interface to accept flush messages on that VLAN.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.147.1.3.1.3
snmpwalk -v2c -c public <target> H3C-SMLK-MIB::h3cSmlkControlVlanListHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.147.1.3.1.3.1
snmpget -v2c -c public <target> H3C-SMLK-MIB::h3cSmlkControlVlanListHigh.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.10.2.147.1.3.1.3.1 s <value>

Start monitoring H3C access switch, ring/dual-uplink topology (Smart Link redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-SMLK-MIB::h3cSmlkControlVlanListHigh OID value, configure state conditions and alerts, and monitor any H3C access switch, ring/dual-uplink topology (Smart Link redundancy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.10h3cHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2h3cCommonHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.10.2.147h3cSmlkH3C-SMLK-MIB
1.3.6.1.4.1.2011.10.2.147.1h3cSmlkObjectH3C-SMLK-MIB
1.3.6.1.4.1.2011.10.2.147.1.3h3cSmlkFlushEnableTableH3C-SMLK-MIB
1.3.6.1.4.1.2011.10.2.147.1.3.1h3cSmlkFlushEnableEntryH3C-SMLK-MIB