Module: H3C-FCOE-MODE-MIB

OID (symbolic): H3C-FCOE-MODE-MIB::h3cFcoeModeCfgMode

OID (numeric): 1.3.6.1.4.1.2011.10.2.135.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: This object specifies the FCoE modes the switch supports.

The object has four available values: 1: non-FCoE mode. 2: FCF mode. 3: NPV mode. 4: Transit mode.

The switch mode can only be converted from non-FCoE mode to one of FCoE modes, or vice versa, but cannot be converted directly among the other three FCoE modes.

To convert among the other three FCoE modes, the switch should first be converted to non-FCoE mode. After converting the switch to non-FCoE mode, FCoE-related configurations in the original FCoE mode will be cleared.

What is h3cFcoeModeCfgMode?

This value configures which Fibre Channel over Ethernet (FCoE) operating mode the switch runs in: non-FCoE, FCF (Fibre Channel Forwarder, acting as a full FC switch), NPV (N-Port Virtualizer, acting as a pass-through), or Transit mode, with the specific rule that the switch can only convert directly between non-FCoE and any one FCoE mode, never directly between two FCoE modes. A storage network administrator sets this when provisioning a switch for converged Ethernet/Fibre-Channel storage traffic, and must remember to step back through non-FCoE mode as an intermediate stage if they need to switch between, say, FCF and NPV modes, since doing so also clears the old mode's FCoE configuration. For example, an administrator moving a switch from FCF mode to NPV mode would first set this to non-FCoE(1), then set it to npv(3), rather than attempting to go straight from FCF to NPV.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.135.1.1
snmpwalk -v2c -c public <target> H3C-FCOE-MODE-MIB::h3cFcoeModeCfgMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.135.1.1.1
snmpget -v2c -c public <target> H3C-FCOE-MODE-MIB::h3cFcoeModeCfgMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.10.2.135.1.1.1 i <value>

Start monitoring H3C data-center switch with FCoE support (FCF/ENode mode) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-FCOE-MODE-MIB::h3cFcoeModeCfgMode OID value, configure state conditions and alerts, and monitor any H3C data-center switch with FCoE support (FCF/ENode mode) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.10h3cHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2h3cCommonHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.10.2.135h3cFcoeModeH3C-FCOE-MODE-MIB
1.3.6.1.4.1.2011.10.2.135.1h3cFcoeModeMibObjectsH3C-FCOE-MODE-MIB
1.3.6.1.4.1.2011.10.2.135.1.1h3cFcoeModeCfgModeH3C-FCOE-MODE-MIB